Outdoor Online Natural Cooling UPS for 4G Rru Station

FOB Price: Get Latest Price
Min. Order: 1 Set
Production Capacity: 5000pieces/Month
Payment Terms: L/C, T/T, Western Union
Basic Info
  • Phase: Three Phase
  • Protection: Sealed Maintenance Free
  • Classification: Lighting/Power
  • Type: Standby
  • Application: Communication
  • Standby Time: 4
Product Description
Product Introduction      
Product Name: Outdoor Online Natural Cooling UPS for 4G RRU station
Product Positioning: To provide an uninterrupted power supply guarantee for 4G RRU station
Application Scenarios: Outdoor derrick, outdoor wall and indoor distribution
Loading Capacity: 500w (three 4G RRU station)
Electricity Time:  4 hours
 
Product Features:
The integration of power supply and battery, small volume and high power density.
Realizing the natural cooling through the cooling fin and insulating the inside cabinet from outside. Reaching a protection grade of IP 65 and thus elevating product operational reliability.
Plug and play with simple maintenance.
Easy of derrick installation.
 
 
Product Model: OP500A
Product Positioning: Only providing power supply guarantee rather than optical fiber distribution and optical transmission device installation site.
Product Superiority: Optical-electric separation, maintenance interface separation and easy of  power supply maintenance.
 
Product Model:OP500A-M
Product Positioning: The integration design of Photo electricity, installation of fiber distribution and optical transmission device.
Product Superiority: A high concentration degree.

 
Cabinet Specification Parameter
Product ModelOP500AOP500A-M
W*D*H500×300×193mm500×300×225mm
Dispositioncabinet, power supply, phosphate battery, monitoringcabinet, power supply, phosphate battery, monitoring, ODF, optical modem positioning, optical cable positioning
Weight  
Protection GradeIP65IP65
Routing ModeBottom inlet-outlet lineBottom inlet-outlet line
Operating  Temperature-20-55c-20-55c
Storage Temperature-25-60c-25-60c
Relative Humidity0-95% non-condensate0-95% non-condensate
Operating Altitude<1500mm, the additional part over 1500mm is used according to regulated GB/T3859.2<1500mm, the additional part over 1500mm is used according to the regulated GB/T3859.2
Noise< /=50dB< /=50dB
 
 
Power Supply Specification Parameter
Rated Power500WSwitching Time0ms
Overall Efficiency93%Operating Modeonline
Warning FunctionOverload, grid abnormal, UPS breakdown, low battery voltage
Protection FunctionShort circuit, overload, over-temperature, low battery voltage, input voltage
Communication FunctionRS485
AC Input 
Input Voltage220Vac
Input Voltage Range90~280Vac
Phase NumberSingle-phase three -wire
Input Frequency Range45~55 Hz
Power Factor≥0.98
AC Output DC Output 
Output Voltage230±1% VacOutput Voltage53.5Vdc
Output Current2.2AOutput Current6A
Output Frequency50±0.2HzOutput Route2(battery + load)
WaveformDC Output 
Power FactorSine wave 
Output Route0.8  
Rated Power4  
      
 
 
Battery Specification Parameter
Battery TypeLithium iron phosphate battery
Battery Capacity10Ah,20Ah
Float Charge Voltage42.00-53.5V
Average Charge Voltage44.00-57.6V
Battery Management 
Battery Oder42.0-43.6V
Standard Charge Current0.1C
Average Charge Current0.075C
Float Charge Current0.03C
Charging Filter Protection  Point0.11C
Battery Discharge Current12A
 
 
Monitoring function
Adjust output voltageAdjust proportion drift charge voltage through monitoring panel, and give the system output voltage based on the judgment of proportion drift charge voltage condition.
 Real - Time Status Acquisition
Battery Management1.       Battery low voltage: when the output voltage is under the setting low-voltage battery, the monitor gives output warning, and dry contact output warning, then the warning LED light. When the voltage restores, the warning stops. There is some return difference between the voltage restoration and warning point.
2. Battery down voltage: under the battery discharge condition, and when output voltage is lower than the setting once down voltage, the system will disconnect battery, and connect relay and output LED warning. When the voltage restore to the setting down voltage, the relay will be closed.
3. The management of battery proportion drift charge: when the charging current of the battery is beyond its maximum charging current, the system gives the battery constant current equalizing charge. And when the constant current equalizing charge is charged to equalizing charge voltage, the system will gives a constant voltage equalizing charge. When the current of constant voltage equalizing charge is smaller than that of equalizing charge turning to floating charge, the current is under a floating charge. And, when floating charge current is larger than that of floating charge turning to equalizing charge, the system gives a equalizing charge. Floating charge continues to the setting time, it will turn to equalizing charge automatically. When the time of constant voltage equalizing charge is beyond the lasting time of the setting equalizing charge, is will turn to floating charge, and the manual equalizing charge turns to equalizing charge.
 
 
This UPS possesses a stronger detection and control function.  With the host computer control, it can detect the working condition of the modules in real time. According to the detecting parameter, it can control the modules working condition, meet the maintenance and management demand of battery pack, and thus making the system work safely and reliably. Through RS485, it can communicate with the host computer, and receive the inquiry, parameter setting and control from it. Then the parameter will be sent to the host computer for centralized management.
 
1. It can read and set the battery proportion drift charge voltage and battery charging   current limiting point.
2. It can read 48V output voltage, current, and inverter output voltage and current.
3. It can read the warning messages of UPS like the malfunction of AC input, low voltage, 48Vshort circuits, 48 current limit, inverter short circuit, inverter overflowing and so on.
Send your message to this supplier
Avatar
Mr. Armani Lee
*From:
To: Mr. Armani Lee
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

Find Similar Products By Category